Buying power from a licensed electricity trader: what customers should check before switching

For most of South Africa’s history a business had one choice of electricity supplier: Eskom or the local municipality. That is changing. Licensed electricity traders now buy power from independent generators and sell it to businesses, using the existing grid to deliver it. For a customer that cannot build its own plant or commit to a long power purchase agreement with a single generator, a trader can offer a simpler route to renewable energy at a competitive price.

The market is new, and the rules that will govern it are not yet final. This article explains how trading works, where regulation stands in November 2026 and what to check before you sign.

What a trader does

A trader does not usually own networks. It contracts with generators on one side and customers on the other, and manages the difference. Because it combines several generators and many customers, a trader can often offer shorter terms, smaller volumes and more flexibility than a direct agreement between one generator and one customer.

The electricity still travels over the national and municipal networks. The arrangement under which a network operator carries a third party’s energy is known as wheeling. The customer’s physical connection does not change. Its distributor continues to deliver electricity and to bill network charges and any energy the customer uses beyond what the trader supplies.

Where regulation stands

Trading electricity requires a licence under the Electricity Regulation Act 4 of 2006. The Act was substantially amended by the Electricity Regulation Amendment Act 38 of 2024, which took effect on 1 January 2025 and provides the framework for a competitive electricity market.

Four facts frame the current position:

  • Licences have been issued. In November 2026 the National Energy Regulator of South Africa (NERSA) was reported as saying that it had issued 25 electricity trading licences.
  • The trading rules are still in draft. NERSA published a third version of its draft Electricity Trading Rules for comment in June 2026. The draft covers direct supply and trading agreements, virtual wheeling, top-up supply and balancing responsibility, and proposes that the market open in phases. When this article was last reviewed, final rules had not been published.
  • Some licences are under challenge. Eskom brought a court review of a number of trading licences. The case has been stayed while the regulatory framework is finalised.
  • A wholesale market is coming. The South African Wholesale Electricity Market is scheduled to launch in April 2027, which will change how traders source and balance energy.

None of this prevents a customer from contracting with a trader now. It does mean that a contract signed today must be able to absorb regulatory change.

Check 1: The licence and the trader behind it

Ask for a copy of the trading licence and read its conditions. Confirm that the entity you are contracting with is the licence holder, not an affiliate. Then look past the licence:

  • Where will the energy come from? Ask whether the trader’s generation is already operating or is still to be built, and what happens to your supply date if construction is late.
  • How does the trader cover shortfalls when its generators produce less than its customers use?
  • What is its financial position, and will a parent company stand behind its obligations?

Check 2: Whether power can be wheeled to your site

Wheeling depends on the network your site is connected to.

  • Eskom-connected sites. A customer supplied directly by Eskom needs the necessary wheeling arrangements and amendments to its supply agreement with Eskom.
  • Municipal sites. If you buy from a municipality, the municipality must have a wheeling framework and tariff in place and must be willing to contract. Not every municipality is at the same stage.
  • Metering. Wheeled energy is reconciled against your consumption in time intervals, so suitable metering is needed.

Establish who is responsible for putting these arrangements in place, how long they will take, and whether the contract is conditional on them. A supply start date that depends on a third party’s approval should not expose the customer to charges if the approval is late.

Check 3: What you are actually buying

Trader offers differ more than their marketing suggests. Clarify:

  • The share of your consumption covered. A trader may supply only part of your needs. The rest remains with your distributor at its normal tariff.
  • The profile. Solar-heavy portfolios deliver in daylight hours. If your consumption peaks in the evening, the saving will be smaller than a headline price suggests.
  • Firm or as-generated. Is the trader promising a fixed volume in each period, or only what its generators produce?
  • How the credit appears on your bill. Understand how wheeled energy is set off against your distributor’s energy charges, and which network and other charges you will keep paying in full.
  • Environmental attributes. If you need to report renewable energy use, or to satisfy customers and export markets, the contract must transfer the renewable energy certificates or equivalent attributes to you, and the trader should warrant that they are not sold twice.

Check 4: The price

  • Fixed price or discount. Some offers are a fixed tariff with annual escalation. Others are a discount to the tariff you would otherwise pay. A discount is only as good as the definition of the reference tariff.
  • Tariff restructuring. Regulated tariff structures change from time to time, including the split between energy charges and fixed or network charges. A change in structure can shrink the portion of your bill that the trader’s energy displaces. The contract should say how the price or discount is reset when that happens.
  • Pass-through charges. Check which wheeling charges, losses, administration fees and new regulatory charges the trader may pass on. The draft Trading Rules propose a non-bypassable charge. Who bears a charge of that kind should be settled in the contract.
  • Take-or-pay. Many contracts require payment for a minimum volume whether or not you use it. Test that minimum against your lowest realistic consumption, including shutdowns.

Check 5: Volume, flexibility and term

Your business will change over the life of the contract. Look for:

  • a tolerance band around forecast consumption before any charges apply;
  • the right to reduce volumes if you install your own solar or storage, improve efficiency or close a site;
  • the right to move the contract to a new site or transfer it to a purchaser of the business; and
  • a term that matches your planning horizon, with a defined exit payment if you need to leave early.

Check 6: What happens if the trader does not deliver

Because your connection stays with your distributor, a trader’s failure should not interrupt your supply. The risk is financial. Energy that the trader fails to deliver will be supplied by the distributor and charged at its tariff. The draft Trading Rules contemplate top-up supply of this kind by the network service provider.

The contract should therefore give you:

  • compensation for shortfalls, based on the extra cost of the replacement energy;
  • a right to terminate for persistent under-delivery; and
  • a right to terminate without penalty if the trader loses its licence, becomes insolvent or can no longer lawfully supply you.

Check 7: Change in law

With final trading rules, a wholesale market and tariff reform all pending, a change-in-law clause is not boilerplate. It should answer three questions. Who bears a new cost imposed on the arrangement? What happens if the rules require the contract to be amended? And can either party exit if the arrangement becomes unlawful, or if the economics change beyond an agreed threshold? A clause that lets the trader pass through every new cost while holding the customer to the full term shifts the regulatory risk entirely to the customer.

Check 8: Credit support, liability and disputes

A trader may ask for a deposit or guarantee. Security should be proportionate to the trader’s real exposure and should reduce as a payment record is established. A customer can reasonably ask for security in the other direction where it is relying on a thinly capitalised trading entity.

Liability caps should not empty the shortfall compensation of value. Billing disputes should go to a quick expert process, with the undisputed portion of each invoice paid in the meantime.

A checklist before switching

  1. Verify the trading licence and the identity of the contracting entity.
  2. Ask where the energy comes from and whether the generation is operating.
  3. Confirm that wheeling to your site is possible and who must arrange it.
  4. Establish what share of your consumption is covered, and in which hours.
  5. Model the saving on your actual consumption profile, not an average.
  6. Check the reference tariff, escalation and all pass-through charges.
  7. Test take-or-pay minimums against your lowest realistic consumption.
  8. Secure flexibility for own generation, site changes and a sale of the business.
  9. Get shortfall compensation and termination rights for non-delivery and loss of licence.
  10. Negotiate a balanced change-in-law clause.
  11. Make sure environmental attributes are transferred to you.
  12. Check your existing supply agreement, lease and funding documents for any consents needed.

How O’Reilly Law can help

O’Reilly Law advises businesses on buying and selling electricity, including power purchase agreements, wheeling arrangements and supply agreements with traders. We review trader proposals against your consumption and risk profile, negotiate the contract terms, and advise on regulatory requirements and disputes. Read more about our energy and projects work.

Question? Contact us for practical advice.

Related reading: Battery storage contracts for commercial sites · Limitation of liability and indemnity clauses

This article is general information and not legal advice. Last reviewed November 2026.